Why Water Cooling In Data Centers Is Not At all times Sustainable

One of many standard tenets of knowledge heart sustainability is that water cooling is best than air cooling. The rationale why is easy: Liquid cooling is extra environment friendly, so it makes use of much less power to ship the identical cooling capability.

That is true – besides when it is not. In some instances, a technique often called water-free cooling, which makes use of minimal quantities of water, may very well be the extra sustainable technique to dissipate warmth from tools inside knowledge facilities.

This is how sustainable knowledge heart cooling with out water works, why it is generally extra environment friendly and how you can determine if water-free cooling is the very best technique to your knowledge heart.

The Fundamentals of Data Center Cooling

There are three frequent methods to cool tools inside knowledge facilities:

  • Blowing air throughout tools to dissipate warmth. That is probably the most simple technique to cool a knowledge heart, however it’s the least environment friendly as a result of air is a lot much less efficient than water for dissipating warmth.

  • Circulating water in shut proximity to tools to dissipate warmth. That is way more environment friendly than air cooling, but in addition dearer to implement.

  • Immersing tools in non-conductive liquid – a observe often called immersion cooling. That is probably the most environment friendly, but in addition costliest, technique to cool a knowledge heart.

In the event you’re on the lookout for a center floor between value and effectivity, you would possibly go for water cooling. 

The Sustainability Affect of Water Cooling

From a sustainability perspective, water cooling’s primary benefit is that it makes use of much less power than air cooling to scale back temperatures by an analogous quantity. This interprets to decrease general electrical energy consumption – which in flip implies that knowledge facilities with water cooling techniques can typically declare to be greener than those who depend on conventional air cooling.

Considered from one other angle, nonetheless, water cooling will not be very sustainable for knowledge facilities positioned in areas with restricted water availability.

The important thing issue to know right here is that the majority or all the water used for water cooling is usually discharged exterior the info heart. In different phrases, it is used just one time with out being recirculated.

In consequence, knowledge facilities that depend on water cooling should consistently ingest water to take care of acceptable temperature ranges. The amount of water might be very vital. As an illustration, Google says its knowledge facilities devour about 450,000 gallons of water every day per facility – an quantity equal to the every day water consumption of about 1,500 properties.

This may not be a difficulty in case your knowledge heart is positioned in a area with ample water. But when water is in brief provide, standard water cooling will not be very sustainable. It may deprive the encompassing pure atmosphere of enough portions of water and/or compete with native communities for water.

This drawback, sadly, is probably going solely to develop worse as groundwater availability continues to lower in lots of areas.

Alternate options to Water Cooling

Confronted with this problem, knowledge heart operators have just a few selections.

One is to go for air cooling, however that comes with its personal sustainability influence. Until you may supply renewable power to energy your air cooling techniques, you may basically simply be buying and selling a poor Water Utilization Effectiveness (WUE) metric for subpar Energy Utilization Effectiveness (PUE).

One other is to improve to immersion cooling. However once more, that is very dear, and isn’t throughout the funds of all knowledge heart amenities.

A 3rd possibility is to undertake a modified type of water cooling, often called water-free or zero-water cooling. These phrases confer with techniques that recirculate water by way of a loop, enabling water-based cooling with minimal water utilization. (Regardless of the phrases “water-free” or “zero-water,” there may be nonetheless a small quantity of water in use – however it’s a fraction of the amount employed by conventional water cooling techniques.)

The financial savings might be dramatic. For instance, Wes Swenson, CEO of Novva Data Centers, advised Data Center Information that by putting in water-free cooling at one 400,000 square-foot facility, his firm diminished water utilization to simply a number of thousand gallons per day – the majority of which was consumed by the power’s staff, not its cooling techniques. Novva’s cooling system requires 10,000 gallons to fill, and as soon as crammed, the water might be reused for an prolonged interval.

Swenson added that this operation additionally reduces the stress positioned on municipal water techniques as a result of it considerably reduces the quantity of grey water discharged from the power. As well as, it not directly reduces power use as a result of much less power is critical to wash discharged water.

Conclusion: Will Water Cooling At all times Look So Inexperienced?

In areas the place water availability will not be a priority, conventional water or liquid cooling for knowledge facilities is prone to stay the go-to strategy. However as an increasing number of communities face water shortages, conventional water cooling will stop to look so inexperienced – and discovering methods to attain the effectivity of water cooling with out consuming huge portions of water will develop into an increasing number of crucial for knowledge heart sustainability.